Low-energy epicardial pacing in children: the benefit of autocapture.

1999

Abstract Background . Permanent cardiac pacing in children results commonly in augmented energy consumption because of the high pacing rates and the ample stimulation safety margin applied in children. Cardiovascular anatomy and limited venous access sometimes preclude the otherwise preferred endocardial approach. In this multicenter patient series, we studied the feasibility, safety, and energy saving obtained by a combination of steroid-eluting epicardial leads with autocapture devices capable of ongoing adjustment of the stimulation output to the prevailing threshold. Methods . Autocapture devices (Pacesetter Microny SR+ and Regency SR+; Pacesetter, Solna, Sweden) and steroid-eluting epi…

Pulmonary and Respiratory MedicineMalemedicine.medical_specialtyPacemaker ArtificialCardiac pacingEpicardial pacingSafety marginElectrocardiographyLow energyElectric Power SuppliesMicrocomputersInternal medicinemedicineHumansChildmedicine.diagnostic_testLife spanbusiness.industryInfantSignal Processing Computer-AssistedEquipment DesignVenous accessSurgeryElectrodes ImplantedEquipment Failure AnalysisChild PreschoolCardiologyFeasibility StudiesSurgeryFemaleCardiology and Cardiovascular MedicinebusinessElectrocardiographyPericardiumSoftwareEndocardiumThe Annals of thoracic surgery
researchProduct

2D Isochronal Correlation Method to Detect Pacing Capture during Ventricular Fibrillation

2009

During ventricular fibrillation (VF), a portion of myocardial tissue can be captured by pacing at a rate near the fibrillation rate. Interruption of ventricular fibrillation can be favored by achieving stable myocardial capture, lowering the energy required for electrical cardioversion. Existence of myocardial capture during electrical stimulation is determined by visual inspection of electrograms (EGM) by an experienced observer. The objective of this work is the development of a semi-automatic method for the detection of myocardial capture based on the 2D correlation of isochronal maps. In 4 isolated rabbit hearts VF was induced by ventricular pacing with an increasing rate. An array of 1…

Fibrillationmedicine.medical_specialtyMyocardial tissuebusiness.industryEpicardial pacingVentricular pacingmedicine.diseaseElectrical cardioversionInternal medicineVentricular fibrillationmedicineCardiologyCorrelation methodmedicine.symptombusiness
researchProduct

Pacemaker therapy in premature children with high degree AV block.

1998

The smallest pacemaker pulse generator and a steroid-eluting bipolar epicardial lead were implanted in two premature children with symptomatic AV block. Stable capture threshold and high amplitude evoked response electrogram resulted in normal function of the pacemaker Autocapture algorithm, which adjusts output 0.3 V above the measured capture threshold. Autocapture had previously been used only with endocardial leads. Longer-term observation is required.

Epicardial leadMalePacemaker ArtificialHigh amplitudebusiness.industryEpicardial pacingInfant NewbornGeneral MedicineTwins MonozygoticPacemaker pulse generatorElectrodes ImplantedHeart BlockAnesthesiaBlock (telecommunications)MedicineHumansCardiology and Cardiovascular MedicinebusinessInfant PrematurePacing and clinical electrophysiology : PACE